Bastion Compute
Modular data centre infrastructure · Australia

Compute that never leaves the country.

Bastion builds small modular data centres on Australian soil — factory-assembled units that arrive complete, rather than one bespoke megaproject built in place. From grid connection to first rack in months, for workloads that are not permitted to go offshore.

1.2MW
Per module, liquid cooled
16wks
Factory to energised
1.25PUE
Design, annualised
100%
Australian owned & operated
01 — The module

A data hall that arrives on a truck.

Each Bastion module is a purpose-built enclosure containing racks, cooling, power distribution, fire suppression and monitoring — assembled and commissioned in the factory, then delivered to a prepared hardstand and connected. No base build, no fit-out, no multi-year construction programme. Capacity is added one module at a time, so the capital follows demand instead of preceding it by three years.

B-40 HD · Plan view Scale 1:100 · Dimensions in metres
CONTAINED COLD AISLE CDU N+1 SWITCH ROOM UPS · SWGR 12.19 m 2.44 m 12 × 100 kW racks Direct-to-chip liquid loop
02 — Specifications

Three standard builds.

Every module ships pre-commissioned with a factory acceptance test certificate. Capacities below are usable IT load at the rack, not gross supply.

ModelIT loadRacksDensityCoolingFootprintLead time
B-20 250 kW 8 30 kW/rack Precision air, N+1 6.06 × 2.44 m 10 weeks
B-40 600 kW 18 35 kW/rack In-row DX, N+1 12.19 × 2.44 m 14 weeks
B-40 HD AI 1.2 MW 12 100 kW/rack Direct-to-chip liquid 12.19 × 2.44 m 16 weeks

All builds to AS/NZS 3000 and AS 1668. Fire detection and suppression to AS 1670. Supply arrangements sized with your distributor — Ausgrid, Endeavour Energy, Essential Energy or the relevant DNSP — as part of the site assessment.

03 — Sovereignty

Some data is not allowed to leave.

Health records, government workloads, financial data and legal discovery all carry residency obligations that offshore hyperscale capacity cannot satisfy. Bastion exists for that boundary.

Residency

Data stays onshore

Every byte is stored and processed within Australian borders. No replication offshore, no foreign subprocessors, no transit through overseas regions.

Certification

Hosting Certification Framework

Built to meet Certified Strategic requirements, including ownership and control conditions for whole-of-government workloads.

Assessment

IRAP to PROTECTED

Facilities assessed by an IRAP assessor against the Information Security Manual, supporting OFFICIAL:Sensitive and PROTECTED classifications.

Ownership

No foreign control

Australian owned, Australian directors, Australian staff. No foreign ownership interest and no offshore parent with access rights.

04 — Deployment

Six stages, one contract.

Power availability decides the programme, so it is settled first. Everything after it runs in parallel with fabrication.

01

Site & power assessment

Available capacity, fibre routes, hardstand condition, planning pathway and an indicative connection cost.

02

Grid connection

Preliminary enquiry and connection application with your distributor, with an accredited ASP Level 3 designer engaged on the augmentation works.

03

Fabrication & FAT

Enclosure built, racks and cooling installed, then a witnessed factory acceptance test before anything leaves the floor.

04

Transport & placement

Delivered by low loader and craned onto the prepared slab. Typically a single day on site.

05

Energisation

Connection to the customer substation, protection testing, commissioning of cooling and suppression, then load on.

06

Operate or hand over

Take the keys, or leave it with us under a managed service with 24/7 monitoring and remote hands.

05 — Identity

The brand system.

The mark is the plan view of a bastion — the angular projection built into a fortress wall so that every approach is covered. It reads as a technical drawing rather than a shield, which is the point: this is infrastructure, not iconography. The green bar inside it is the module.

Lockups
Bastion Compute
Primary horizontal lockup
Bastion Compute
Reversed, on ink
Mark only — solid, standard, single colour. Clear space equals the height of the inner bar on all sides. Minimum size 18 px.
Palette
Bastion Navy
#0C1A2B
Signal Green
#0A7A4E
Steel
#5D7086
Cold Paper
#F4F6F8
Signal (dark UI)
#3ECF8E
Ochre — alerts only
#9C6212
Typography
Archivo 700 — display
Energised in sixteen weeks
IBM Plex Sans 400 — body
Purpose-built enclosures, commissioned before they ship.
IBM Plex Mono 500 — data & labels
1.2 MW · PUE 1.25 · 100 kW/rack